top of page

PIECAL 422 Plus

The Only 2 in 1 Thermocouple & FULL FUNCTION Milliamp Calibrator on the market!

 

Calibrate all your thermocouple instruments AND your milliamp loops with the PIE 422Plus. It has all the functions of a 14 type thermocouple calibrator and can source 0 to 24 milliamps or simulate a two wire transmitter like a milliamp calibrator.

 

You may also perform stand alone calibrations of two wire transmitters by simultaneously supplying the thermocouple input signal while supplying the 24 volts to power up the transmitter and monitoring the milliamp output signal.

​

Powers HART™ transmitters with built-in 250 ohm resistor simplifying hookups with HART communicators.

PIECAL 422 Plus.jpg

The PIE 422Plus allows you to quickly diagnose ground fault and current leakage with the patented loop diagnostic technology (US Patent# 7,248,058)

​

Stop carrying around a millivolt source and thermocouple tables. The PIECAL 422Plus works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II).

 

Easily set any value quickly to within 0.1° with the adjustable “EZ-DIAL” plus store any three temperatures for instant recall with the EZ-CHECK™ switch.

 

You may also calibrate from -13.000 to +80.000 mV. Connect your thermocouple and the PIE 422Plus measures the probe in degrees C or F. Secondary display shows the millivolt value corresponding to the thermocouple temperature.

 

The internal cold junction thermistor is accurate to ±0.05°C. The sensor is thermally bonded to an isothermal mass including brass blocks with screw terminals for connection of bare thermocouple wires along with a miniature thermocouple connector for fast connections. An extremely stable voltage reference and low drift components make it more accurate than most other handheld & benchtop thermocouple calibrators.

The PIE 422Plus is capable of meeting the requirements of an AMS 2750 Field Test Instrument when calibrated by an accredited laboratory (such as Haven Automation Ltd - UKAS Laboratory Number 0295).

 

With the built-in milliamp calibrator, you can check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp loop. It can be used at any access point in your loop. Source & Read 0.000 to 24.000 mA, Simulate a 2 Wire Transmitter or use the PIE 422Plus to simultaneously power your 2 Wire Transmitter and measure its output while simulating the sensor input.

 

Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30 and 60 seconds.

 

With the PIE 422Plus, you can check & calibrate all your thermocouple instruments, measure thermocouple Sensors, and calibrate 4 to 20 milliamp instruments. It has an automatic indication of connections on the display for simple hookups.

 

You can carry it without worry – it comes protected with a rubber boot and rugged, low profile switches. The PIE 422Plus is easy to operate even in dark areas with the backlit display.

PIE Logo.png